1*8 PLC splitter (SC/UPC) 1*16 PLC splitter (SC/APC)
Table 1 – 1×N PLC Splitter
Parameters | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | 1×128 |
Operating Wavelength (nm) | 1260~1650 | ||||||
Fiber Type | G657A1 or customer specified | ||||||
Insertion Loss (dB)(P/S Grade) | 3.8/4.0 | 7.1/7.3 | 10.2/10.5 | 13.5/13.7 | 17/17.4 | 20./20.4 | 23.8/24.2 |
Return Loss (dB) (P/S Grade) | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 |
Operating Temperature (℃) | -40~85 | ||||||
Storage Temperature (℃) | -40~85 |
Table 2 – 2×N PLC Splitter
Parameters | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | 2×128 |
Operating Wavelength (nm) | 1260~1650 | ||||||
Fiber Type | G657A1 or customer specified | ||||||
Insertion Loss (dB)(P/S Grade) | 4.0 | 7.6 | 11.0 | 14.4 | 17.5 | 21.0 | 24.5 |
Return Loss (dB) (P/S Grade) | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 |
Temperature Stability (-40~85 ℃)(dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 | 0.5 |
Operating Temperature (℃) | -40~85 | ||||||
Storage Temperature (℃) | -40~85 |
Notes:
1. Specified without connectors.
2. Add an additional 0.15dB loss per connector.
Dimension